Typ EWL-PAB, or

Variations: 9

Note: Product illustration may differ

Product images
Product information

EWL-PAB cable protection conduits are made of a specially modified UV-stabilized polyamide 6 in the signal color orange (RAL 2003).

They are characterized by excellent self-extinguishing properties as well as high crush and impact resistance and are suitable for

static and slightly dynamic applications involving low to medium mechanical loads.

Applications:

Electromobility

Vehicle engineering

Properties
Typ EWL-PAB, or Halogen-free
Typ EWL-PAB, or UV-resistant
Typ EWL-PAB, or Indoor
Typ EWL-PAB, or Outdoor
Typ EWL-PAB, or ROHS Compliant
Typ EWL-PAB, or filters.VERBRENNUNGSBESTTEST_ECE324R118
Typ EWL-PAB, or Railroad EU approval
Typ EWL-PAB, or CURUS-Approval
Typ EWL-PAB, or Made in Germany
Material
Material

mod. polyamide PA 6

System tear-out strength
System tear-out strength

> 270 N According to IEC EN 61386 M25/P21 Testing at 23 °C Fitting M-PRO

Temperature
Temperature

-45 °C–120 °C short term 160 °C

Fire properties EN45545
Fire properties EN45545

C.I.T. R22 / R23 HL3 : 0.61 NF X 70-100-1/-2 600°C (1112 °F)

Ds (max.) R22 / R23 HL3 : 68 ISO 5659-2 (25 KW/m²)

LOI R22 / R23 HL3 : 32 ISO 4589-2

Fire classification
Fire classification

acc. to UL94: V0 self-extinguishing

Fire properties NFPA130
Fire properties NFPA130

ASTM E 162

ASTM E 1354

ASTM E 662

Boeing BSS 7239

Boeing BSS 7242

Bombardier SMP 800-C

Crush resistance class
Crush resistance class

> 550 N 50 x 50 mm According to IEC EN 61386 M25/P21 Testing at 23 °C

> 950 N 100 x 100 mm According to IEC EN 61386 M25/P21 Testing at 23 °C

Chemical resistance
Chemical resistance

Alcohol

Mineral oils

Greases

Fuels

Flexural fatigue
Flexural fatigue

According to IEC EN 61386

Cycles: > 8000 ~

ECE 324 R 118
ECE 324 R 118

Annex 6+8

Impact strength
Impact strength

3 According to IEC EN 61386 M25/P21 Testing at -25 °C

Product reviews